Standing Seam Metal Roofing

Snap On Panels

Durable, lightweight Snap-on Standing Seam and Batten panels are used for roofing, fascia and mansard applications. They are designed for easy handling, workability and fast assembly in the field. Available in aluminum or steel with a warranted twenty-year finish in an assortment of colors.

Structural Panels

Economical Structural Standing Seam and Batten panel are used in roofing and fascia applications. They have unique architectural aesthetics and are also exceptionally weather tight. Panels may be installed either spanning structural supports, a maximum 5'-0" o.c., or over solid decking.

Custom Flashings

Custom Formed Coping, Gravel Stop and Flashings

Features
  • 30 standard colors
  • 10' standard lengths
  • Formed and welded miters
Materials
  • G90 galvanized steel
  • Aluminum
  • Copper
  • Stainless Steel
  • Prefinished steel and aluminum
Finishes
  • Kynar 500
  • Baked enamel
  • Anodized
  • Mill finish

Prefinished Sheets or Aluminum Flat Sheets and Coil

General Info
  • Kynar 500 fluoropolymer coating system is on of the highest quality architectural finishes available
  • Standard Colors: Dark Bronze, Mansard Brown, Matte Black, Musket Gray, Slate Gray, Stone White, Sandstone, Sierra Tan, Terra Cotta, Colonial Red, Burgundy, Arcadia Green, Forest Green, Teal, Military Blue, Interstate Blue, Hartford Green, Granite, Hemlock Green, Charcoal, Berkshire Blue, Almond, Cardinal Red, Bone White
  • Premium Colors: Copper Penny, Aged Copper, Champagne, Silver, Zinc
  • Custom Colors: Available on inquiry

Specifications

Roofing Specifications

  • Snap-On Specifications
    1. PANELS: Panels shall be Baird & Wilson Sheetmetal, Inc., Knoxville, TN, (865) 523-9982. Snap-on Standing Seam or Batten seam panels, roll-formed in continuous lengths. Material shall be 24 ga. steel or .032 aluminum. Seam spacing shall be selected from available on-center dimensions.
    2. FINISH: Panels shall be finished with Kynar 500, two coat 70% Kynar 500 finish, applied over an epoxy prime coat. Panel color shall be selected from manufacturer's standard colors. A twenty-year finish warranty shall be supplied upon request.
    3. TRIM: All flashing and trim shall be of same material, gauge and finish as panels.
    4. INSTALLATION: Baird & Wilson Snap-on panels shall be installed over solid decking with an underlayment of 30#felt. Snap-on panels shall be fastened using non-penetrating hold-down clips 24" o.c. (minimum). Minimum slope is 3:12
  • Structural Panels
    1. PANELS: Panels shall be Baird & Wilson Sheetmetal, Inc., Knoxville, TN, (865) 523-9982. Snap-on Standing Seam or Batten seam panels, roll-formed in continuous lengths. Material shall be 24 ga. steel. Seam spacing shall be selected from available on-center dimensions.
    2. FINISH: Panels shall be finished with Kynar 500, two coat 70% Kynar 500 finish, applied over an epoxy prime coat. Panel color shall be selected from manufacturer's standard colors. A twenty-year finish warranty shall be supplied upon request.
    3. TRIM: All flashing and trim shall be of same material, gauge and finish as panels.
    4. INSTALLATION: Baird & Wilson Snap-on panels shall be installed by qualified installers, utilizing non-penetrating, concealed hold-down clips. Minimum slope is 2:12

Coping/Gravel Stop/Flashing Specifications

  • Coping
    1. Coping system shall be manufactured by Baird & Wilson Sheetmetal, Inc., Knoxville TN (865) 523-9982. The coping shall press on to saddles and attach without the use of exposed fasteners. Coping shall be .050 or .063 aluminum or 24 ga. steel (architect specify) with 6" wide splice plates or cover plates to match coping. Saddles shall be 20 ga. galvanized steel and anchored to top of wall using approved fasteners.
  • Gravel Stop
    1. All formed gravel stop and flashing trim shall be manufactured by Baird & Wilson Sheetmetal, Inc., Knoxville TN (865) 523-9982. Gravel stop, flashing and trim shall be formed aluminum, of gauge selected by the architect, or 24 ga. steel, secured by continuous cleat and provided with 6" wide splice plates or cover plates at joints.
    2. FINISH: Coping gravel stop and flashing shall be finished with Kynar 500, baked enamel, anodized, or mill finish as selected by the architect.